Data Center/Supercomputer Liquid Cold Plates Suppliers

Home / Product / Liquid Cold Plate / Data Center/Supercomputer Liquid Cold Plate
About
Changzhou Bingrui Heat Exchanger Technology Co., Ltd.

We are a professional designer and manufacturer of aluminium heat exchangers, dedicated to offering international customers cooling solutions. Each of us adheres to the self-working principles of "make the product, pursue the quality". Data Center/Supercomputer Liquid Cold Plates Suppliers and Company in China.

The company covers an area of more than 6,000 square meters and currently has 108 employees. Our production process strictly follows the ISO9001 quality system, and our products can be customized according to the various requirements of customers. Custom Data Center/Supercomputer Liquid Cold Plates Company.

Aluminium heat exchangers are widely used in compressors, dryers, construction machinery, agriculture and forestry industry, various tractors, engine cooling units, hydraulic system, automobiles, air separation sectors. Wholesale Data Center/Supercomputer Liquid Cold Plates. According to the difference of the cooling medium, aluminium heat exchanger is also named air coolers, radiators, oil coolers, hydraulic oil cooler, aluminium plate bar heat exchanger, etc.

Based on the principle of "high quality is the life of enterprise, good reputation is the foundation in the market", we have complete product inspection facilities and can supply high quality products and complete services to customers. We welcome customers and friends from around the world to visit us for business negotiations and collaboration opportunities.

FACTORY
  • Workshop
  • Workshop
  • Workshop
  • Workshop
  • Workshop
  • Workshop
  • Workshop
  • Workshop
  • Workshop
  • Workshop
  • Workshop
  • Workshop
Message Feedback
News
Industry knowledge
How are liquid cold plates integrated into Data Center/Supercomputer?
Liquid cold plates are integrated into data centers and supercomputers to provide efficient cooling for high-density computing components such as processors, memory modules, and high-performance GPUs. Here's how liquid cold plates are typically integrated, along with considerations for installation, mounting, and connection to other system components:
Installation Location:
Liquid cold plates are typically installed within or adjacent to electronic racks or server cabinets. They may be mounted directly onto the heat-generating components, such as CPUs or GPUs, or positioned in close proximity to effectively dissipate heat.
Mounting Method:
Liquid cold plates are mounted securely onto the surface of heat-generating components using mounting brackets, thermal interface materials (TIMs), or other attachment mechanisms. The mounting method ensures good thermal contact between the cold plate and the heat source for efficient heat transfer.
Fluid Connections:
Liquid cold plates are connected to a closed-loop liquid cooling system within the data center or supercomputer infrastructure. Fluid connections involve inlet and outlet ports on the cold plate that are connected to supply and return lines of the cooling system.
Considerations for fluid connections include the use of compatible fittings, seals, and tubing materials to prevent leaks and ensure reliable fluid flow.
Integration with Electronic Racks:
Liquid cold plates are often integrated directly into electronic racks or server cabinets, either as standalone units or as part of a liquid cooling manifold system. Integration with electronic racks requires careful consideration of space constraints, airflow patterns, and cable management to ensure proper fit and functionality.
Cold plates may be installed within specially designed rack-mounted chassis or enclosures to facilitate easy installation, maintenance, and serviceability.
Heat Exchanger Connection:
In some cases, liquid cold plates are connected to external heat exchangers or cooling towers to dissipate heat from the liquid coolant. Heat exchangers may be located within the data center facility or mounted externally, depending on space availability and cooling requirements.
Considerations for heat exchanger connection include the routing of coolant lines, the selection of appropriate heat exchanger technologies (e.g., air-cooled or liquid-cooled), and the integration of control systems for temperature regulation.
Thermal Management System Integration:
Liquid cold plates are part of a larger thermal management system that includes components such as pumps, reservoirs, filters, and control systems. Integration with the thermal management system involves coordinating the operation and control of cooling components to maintain optimal operating temperatures for electronic components.
Considerations for thermal management system integration include compatibility between components, communication protocols, and system scalability to accommodate future expansion or upgrades.
Overall, the integration of Data Center/Supercomputer Liquid Cold Plate into data centers and supercomputers requires careful planning, coordination, and consideration of various factors such as space constraints, thermal performance requirements, system compatibility, and ease of maintenance. Collaboration between system designers, manufacturers, and facility engineers is essential to ensure the successful implementation of liquid cooling solutions in high-performance computing environments.

 What types of cooling fluids are used in liquid cold plates for Data Center/Supercomputer?
In Data Center/Supercomputer liquid cold plates several types of cooling fluids can be used, each with specific thermal properties, environmental impacts, and compatibility considerations. Here are some common types of cooling fluids used in liquid cooling systems for data centers and supercomputers:
Water:
Thermal Properties: Water has excellent thermal conductivity, making it an efficient coolant for transferring heat away from electronic components. It can absorb large amounts of heat energy and dissipate it efficiently.
Environmental Impact: Water is non-toxic and readily available, making it environmentally friendly. However, it can be corrosive to certain metals if not properly treated or if impurities are present.
Compatibility: Water is generally compatible with most system components, including copper, aluminum, and various plastics commonly used in liquid cooling systems. However, precautions must be taken to prevent corrosion and microbial growth.
Glycol-Water Mixtures (Antifreeze):
Thermal Properties: Glycol-water mixtures, such as ethylene glycol or propylene glycol, are commonly used as antifreeze agents in liquid cooling systems. They have lower thermal conductivity compared to water but offer freeze protection and improved fluid stability.
Environmental Impact: Glycol-based coolants are toxic and require careful handling to prevent environmental contamination. Proper disposal and recycling procedures are necessary to minimize environmental impact.
Compatibility: Glycol-based coolants may have compatibility issues with certain materials, such as elastomers, seals, and gaskets. System components must be selected or treated to withstand exposure to glycol-based fluids.
Fluorinated Fluids:
Thermal Properties: Fluorinated fluids, such as perfluorocarbons (PFCs) or fluorinated oils, offer excellent thermal stability and dielectric properties. They have high boiling points and low viscosity, making them suitable for high-temperature applications.
Environmental Impact: Fluorinated fluids are chemically stable and non-toxic, but they have a high global warming potential (GWP) and can contribute to environmental degradation if released into the atmosphere. Proper handling and disposal procedures are necessary to mitigate environmental impact.
Compatibility: Fluorinated fluids are compatible with a wide range of materials, including metals, plastics, and elastomers commonly used in liquid cooling systems. However, they may not be suitable for all applications due to environmental considerations.
Dielectric Coolants:
Thermal Properties: Dielectric coolants are non-conductive fluids designed for cooling electronic components while providing electrical insulation. They offer excellent thermal stability and compatibility with sensitive electronic devices.
Environmental Impact: Dielectric coolants are generally non-toxic and environmentally friendly. However, some formulations may contain additives or surfactants that require proper disposal procedures to minimize environmental impact.
Compatibility: Dielectric coolants are compatible with a wide range of system components, including metals, plastics, and elastomers. They are commonly used in high-performance computing applications where electrical insulation is critical.
When selecting a cooling fluid for liquid cold plates in data centers and supercomputers, factors such as thermal performance, environmental impact, compatibility with system components, and operational requirements must be carefully considered. Manufacturers and system integrators evaluate these factors to choose the most suitable coolant formulation for specific applications, ensuring efficient and reliable cooling of electronic components while minimizing environmental impact and operational risks.